Passive Fire Protection – Fire Rated Products, Systems and Solutions

Trafalgar Fire – FyreCOLLAR Cast In Stack High Cast Collar

$0.00

Trafalgar’s Australian Made FyreCOLLAR Cast-in High Top range of fire collars provides a full range of solutions for use in both stack pipe and floor waste applications, with up to 4 hours across a huge range of common pipes types and sizes.  Specifically for stack and plumbing pipes, locally made, injection moulded and designed to be cast directly into concrete floor slabs for the provision of plastic pipe penetrations without the need to pre-install sections of pipework, decreasing the amount of time spent on site.

These collars are designed for use in concrete floor slabs up to 250mm thick, where the head of the high cast-in fire collar extends above the surface of the floor so that sections of pipe are not needed as part of the installation process. Once the concrete is set, simply run your plastic or metal pipes through the collars which are fitted with a rubber gasket to prevent smoke leakage through the penetration.

The high top cast-in fire collars are available in three sizes each suitable for a range of pipe sizes:

  • 40mm – 65mm for 40mm, 50mm and 65mm pipes
  • 80mm – 100mm for 80mm and 100mm pipes

Options:
FyreCOLLAR Cast In Stack High Cast Collar 40-65mm
FyreCOLLAR Cast In Stack High Cast Collar 80-100mm

Description

Key Features

  • Pipes: PVC, HDPE, PP-R, PP, RAUPIANO
  • Polypropylene body material gives high moisture resistance and flexural strength
  • The high-grade intumescent formulation for fire performance
  • Suitable for slabs up to 250mm
  • High profile design saves time on site
  • Rubber seal to stop water/debris
  • Plastic cap included for protection during installation
  • Flexible rubber membrane absorbs pipe movement and vibration
  • Now approved for copper and steel pipes up to 100mm diameter with TWRAP™ and UniGUARD™ installed on the top side of the slab to protect against heat
    transfer through the metal pipe.
  • The FyreCOLLAR Cast-In High range is also fire tested for up to 2 x pair coil bundles with FR insulation and associated cables. This covers -/240/90 wrap free, refer to the approvals in the Technical Manual for further details.

Please check with the manufacturer for the most up-to-date system applications, installation requirements and test data

FyreCOLLAR Cast-In Stack High Collar Technical Manual
FyreCOLLAR Cast- In FCO-3475 Revision Test Report
FyreCOLLAR Range BIM Models
Article- Fire Collars: Are They As Simple As Many Think?
Article- The history of Fire Collars
Blog- Understanding Different Fire Collars Stack V/S Floor Waste Applications By John Rakic

Additional information

Type

FyreCOLLAR Cast In Stack High Cast Collar 40-65mm, FyreCOLLAR Cast In Stack High Cast Collar 80-100mm